Valvoline - Ooltewah (21828)
Site Acreage: 1.46 AC Building SF: 2,989 SF Structural Type: Wood Frame/ Wood Stud Brief Project Description: Ground up two bay Valvoline Instant Oil Change with a basement and 21" thick mat foundation. The building includes waterproofing, EFIS, Brick, and Shingle roofing. 2. Site Construction 2-c Erosion Control Yes 2-d Sitework, Grading Yes-Excavated materials can only be utilized behind curbs or landscape areas. Excavated Materials are to be removed from site when excavated. Building and trenches are to be backfilled and compacted only with the stone materials as stated in the plans/ Include excavating for the basement/ Please include #57 stone backfill (Furnish and install) for the backfill of pit walls, also include the GeoFabric between earth and stone material/ Please include stone under pit slab furnish and install/ Please include the sump pump manholes furnish and install/ On site topsoil will be reused/ Please include unit prices for rock removal- please reach out to tdaniel@cbigc.com for unit price sheet This is required for your bid to be considered. / If you are including concrete, please include a full site package (Bollards, Lightpole bases, Setting Bike Rack, Dumpster Footings, ect.) 2-f Site Utilities (Storm, Water, Sewer) Yes- Please include foundation sump pump manhole and the foundation drain. Find depths on Grading plan (-8.875').
Geo Report
(click to expand/collapse)

Name | Size | ||
Geo Report - Ooltewah, TN(Version=1) | 4.0 MB |
Spec
(click to expand/collapse)

Name | Size | ||
VIOC Project Manual | 9.8 MB |